Mitsubishi Electric MR-J4 Instruction Manual page 177

Servo amplifers mr-j4-_b_(-rj) melservo-j4
Hide thumbs Also See for MR-J4:
Table of Contents

Advertisement

5. PARAMETERS
No.
Symbol
PC04
**COP1
Function selection C-1
Select the encoder cable communication method selection.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PC05
**COP2
Function selection C-2
Set the motor-less operation and [AL. 9B Error excessive warning]. The motor-less operation
is not available in the linear servo motor control mode, fully closed loop control, and DD motor
control mode.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PC06
*COP3
Function selection C-3
Select units for error excessive alarm level setting with [Pr. PC01] and for error excessive
warning level setting with [Pr. PC38]. The parameter is not available in the speed control
mode and torque control mode.
Setting
digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
PC07
ZSP
Zero speed
Used to set the output range of ZSP (Zero speed detection).
ZSP (Zero speed detection) has hysteresis of 20 r/min or 20 mm/s.
PC08
OSL
Overspeed alarm detection level
This is used to set an overspeed alarm detection level.
When you set a value more than "servo motor maximum speed × 120%" or "linear servo motor
maximum speed × 120%", the set value will be clamped.
When you set "0", the value of "(linear) servo motor maximum speed × 120%" will be set.
Name and function
Explanation
For manufacturer setting
Encoder cable communication method selection
0: Two-wire type
1: Four-wire type
When using an encoder of A/B/Z-phase differential output method,
set "0".
Incorrect setting will result in [AL. 16 Encoder initial communication
error 1]. Or [AL. 20 Encoder initial communication error 1] will
occur. Setting "1" will trigger [AL. 37] while "Fully closed loop
control mode (_ _ 1 _)" is selected in [Pr. PA01] (except MR-J4-
_B_-RJ).
Explanation
Motor-less operation selection
0: Disabled
1: Enabled
For manufacturer setting
[AL. 9B Error excessive warning] selection
0: [AL. 9B Error excessive warning] disabled
1: [AL. 9B Error excessive warning] enabled
The setting of this digit is used by servo amplifier with software
version B4 or later.
Explanation
For manufacturer setting
Error excessive alarm/error excessive warning level unit selection
0: Per 1 rev or 1 mm
1: Per 0.1 rev or 0.1 mm
2: Per 0.01 rev or 0.01 mm
3: Per 0.001 rev or 0.001 mm
5 - 36
Initial
Setting
value
range
[unit]
Refer to the
"Name and
function" column.
Initial
value
0h
0h
0h
0h
Refer to the
"Name and
function" column.
Initial
value
0h
0h
0h
0h
Refer to the
"Name and
function" column.
Initial
value
0h
0h
0h
0h
50
0
[r/min]/
to
[mm/s]
10000
0
0
[r/min]/
to
[mm/s]
20000

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents