Siemens SIMATIC S5-90U System Manual page 545

Table of Contents

Advertisement

S5-90U/S5-95U
Oper-
Permissible
RLO*
ation
Operands
(STL)
1
Timer Operations (cont.)
SE
T
Y
SD
T
Y
SS
T
Y
SF
T
Y
R
T
Y
Counter Operations
CU
C
Y
CD
C
Y
S
C
Y
R
C
Y
Arithmetic Operations
+F
N
-F
N
Comparison Operations
!=F
N
><F
N
*
1 RLO dependent ?
EWA 4NEB 812 6115-02b
Operations List, Machine Code and List of Abbreviations
S5-90U
Execution Time in µs
2
3
Onboard
Ext. I/O
N
Y
64
N
Y
65
N
Y
65
N
Y
64
N
Y
21
N
Y
35
N
Y
40
N
Y
62
N
Y
17
N
N
19
N
N
22
Y
N
20
Y
N
22
2 RLO affected ?
3 RLO reloaded?
S5-95U
Execution Time in µs
Onboard
Ext. I/O
64
Start a timer (stored in
ACCU 1) as extended pulse
(signal contracting and
stretching) on the leading edge
of the RLO.
65
Start an on-delay timer (stored
in ACCU 1) on the leading
edge of the RLO.
65
Start a stored on-delay timer
(stored in ACCU 1) on the
leading edge of the RLO.
64
Start an off-delay timer (stored
in ACCU 1) on the trailing edge
of the RLO.
21
Reset a timer.
35
Counter counts up 1 on the
leading edge of the RLO.
40
Counter counts down 1 on
leading edge of the RLO.
62
Set counter if RLO="1".
17
Reset counter if RLO="1".
19
Add two fixed-point numbers:
ACCU 1+ACCU 2.
CC 1 / CC 0 / OV are affected.
22
Subtract one fixed-point
number from another:
ACCU 2 - ACCU 1.
CC 1 / CC 0 / OV are affected.
21
Compare two fixed-point
numbers for "equal to": If
ACCU 2=ACCU 1, the RLO
is "1".
CC 1 / CC 0 are affected.
22
Compare two fixed-point
numbers for "not equal to": If
ACCU 2 ACCU 1, the RLO
is "1".
CC 1 / CC 0 are affected.
Function
A-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic s5-95u

Table of Contents