Altitude
• 2000 m max.
Ambient temperature
• -20 to +50 °C (-4 to +122 °F)
Relative humidity
• Suitable for outdoors
(only with IP65 / Type 4X / NEMA 4X Enclosure)
Installation category
• II
Pollution degree
• 4

Approvals

The device nameplate lists the approvals that apply to your device.
Note:
• General
CSA
US/C
• Hazardous
Non-incendive (Canada)
A5E33329501
SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS
, CE, FM, UL listed, C-TICK
CSA Class I, Div. 2, Groups A, B, C, D; Class II,
Div 2, Groups F, G; Class III