Configuring alarms
7.3 Configuring DB2 alarms
7.3.6
Configuring runtime settings
Requirement
● A PC system with WinCC RT Advanced or a SIMATIC Panel has been added.
See Inserting the SIEMENS PC system and runtime (Page 47) or Adding a SIMATIC
Panel (Page 54)
Procedure
Proceed as follows to configure the runtime settings for displaying DB2 alarms:
1. In the project tree, double-click under WinCC RT Advanced on "Runtime settings", for
example "PC system_1 > HMI_RT_1 > Runtime settings".
2. In the Runtime settings, click on "Alarms" in the area navigation.
3. Select the following checkboxes in the "System alarms" section:
– S7 diagnostic messages (number)
– Display alarm text
Figure 7-3
Settings for displaying DB2 alarms
104
SINUMERIK Integrate Create MyHMI / WinCC V13 SP1
Configuration Manual, 11/2014