1.5 Maintenance Service Data of Cooling System

Tension pulley
P/A:
37546-21700
(For jacket water)
P/A:
Thermostat
35C46-05200
(For air cooler)
P/A:
37546-40700
(For air cooler)
Water pump
For air cooler water pump
2-12
Item
Inside diameter of pulley bearing fit
Bearing
Outside diameter of bracket bearing fit
Valve opening temperature
Temperature at which valve lift becomes
9 [0.35] or more
Valve opening temperature
Temperature at which valve lift becomes
10 [0.433] or more
Valve opening temperature
Temperature at which valve lift becomes
11 [0.43] or more
Outside diameter of case bearing housing
Bearing
Outside diameter of shaft fit to bearing
Impeller front clearance
Impeller water pump shaft interference
Case bearing
inside diameter of counterbore
Bearing
Outside diameter of shaft fit to bearing
Impeller front clearance
Nominal
Standard value
value
51.970 to 52.000
ø52 [2.05]
[2.0461 to 2.0472]
Outside
51.987 to 52.000
ø52 [2.05]
diameter
[2.0467 to 2.0472]
Inside
19.988 to 20.000
ø20 [0.79]
diameter
[0.7869 to 0.7874]
19.987 to 20.000
ø20 [0.79]
[0.7869 to 0.7874]
69 to 73ºC
[156 to 163ºF]
33 to 37°C
[91.4 to 98.6°F]
69 to 73ºC
[156 to 163ºF]
ø80
79.988 to 80.018
[3.15]
[3.1494 to 3.1503]
ø90
89.987 to 90.022
[3.54]
[3.5428 to 3.5442]
ø80
79.985 to 80.000
[3.15]
[3.1490 to 3.1496]
Outside
diameter
ø90
89.985 to 90.000
[3.54]
[3.5427 to 3.5433]
Inside
ø40
39.988 to 40.000
diameter
[1.57]
[1.5743 to 1.5748]
ø40
40.002 to 40.013
[1.57]
[1.5749 to 1.5753]
0.72
0.14 to 1.30
[0.0283]
[0.0055 to 0.0445]
ø20
0.024 to 0.060
[0.79]
[0.0009 to 0.0024]
Pump
ø62
61.988 to 62.018
case
[2.44]
[2.4405 to 2.4416]
Bearing
ø68
67.961 to 67.991
cover
[2.6]
[2.6756 to 2.6768]
Outside
ø28
27.990 to 28.000
diameter
[1.10]
[1.1020 to 1.1024]
Inside
ø68
67.987 to 68.000
diameter
[2.6]
[2.6766 to 2.6772]
ø28
28.002 to 28.015
[1.10]
[1.1024 to 1.1030]
0.8
0.5 to 1.1
[0.031]
[0.0197 to 0.0433]
Limit
value
Valve open temperature
stamp: 71ºC [160ºF]
85ºC
[185ºF]
Opening temperature
stamp 35ºC [95ºF]
50°C
[122ºF]
Valve open temperature
stamp: 71ºC [160ºF]
85ºC
[185ºF]
80.025
[3.1506]
90.025
[3.5443]
39.995
[1.5746]
Unit: mm [in.]
Remarks