Maintenance Service Data Of Cooling System - Mitsubishi S12A2 Service Manual

Table of Contents

Advertisement

Chapter 2 SERVICE DATA

1.5 Maintenance Service Data of Cooling System

P/N:32645-92020
Water
P/N:32653-05010
pump
Tension
pulley
P/N:32645-18401
Fan
Valve opening temperature
Thermo-
stat
Temperature at which valve lift becomes 10 [0.433] or more
2-14
Item
Inside diameter of pulley
bearing fit
Outside
diameter
Bearing
Inside
diameter
Bracket bearing
Outside diameter to fit
Pulley bearing
inside diameter of counter-
bore
Outside
diameter
Bearing
Inside
diameter
Outside diameter of bracket
bearing fit
Inside diameter of pulley
bearing fit
Outside
diameter
Bearing
Inside
diameter
Bracket bearing
Outside diameter to fit
Inside diameter of pulley
bearing fit
Outside
diameter
Bearing
Inside
diameter
Outside diameter of bracket
bearing fit
Primary
Second-
ary
Nominal
Standard value
value
79.961 to 79.991
ø80 [3.15]
[3.1481 to 3.1492]
79.987 to 80.000
ø80 [3.15]
[3.1491 to 3.1496]
34.988 to 35.000
ø35 [1.38]
[1.3775 to 1.3780]
34.984 to 35.000
ø35 [1.38]
[1.3773 to 1.3780]
51.970 to 51.995
ø52 [2.05]
[2.0461 to 2.0470]
51.987 to 52.000
ø52 [2.05]
[2.0467 to 2.0472]
19.988 to 20.000
ø20 [0.79]
[0.7869 to 0.7874]
19.987 to 20.000
ø20 [0.79]
[0.7869 to 0.7874]
89.972 to 89.994
ø90 [3.54]
[3.5422 to 3.5431]
89.985 to 90.000
ø90 [3.54]
[3.5427 to 3.5433]
39.988 to 40.000
ø40 [1.57]
[1.5743 to 1.5748]
39.984 to 40.000
ø40 [1.57]
[1.5742 to 1.5748]
ø120
119.972 to 119.994
[4.72]
[4.7233 to 4.7242]
ø120
119.985 to 120.000
[4.72]
[4.7238 to 4.7244]
44.988 to 45.000
ø45 [1.77]
[1.7712 to 1.7717]
44.984 to 45.000
ø45 [1.77]
[1.7710 to 1.7717]
69 to 73°C
[156 to 163°F]
72 to 76°C
[162 to 169°F]
85°C [185°F]
Unit: mm [in.]
Limit
Remarks
value
Valve opening tempera-
ture stamp: 71°C
[160°F]