Chapter 10 COOLING SYSTEM
2.10 Air Cooler Coolant Pump - Assemble
10-22
Application of grease
Fill with 31 grams grease.
Air Cooler Coolant Pump - Assemble
Application of Loctite
22.5 ± 2.25 N·m
{2.29 ± 0.23 kgf·m}
[16.6 ± 1.66 lbf·ft]
Apply sealant (ThreeBond 1102) to
outer peripheral surface of unit seal.
Replace
Make it flush
0.5 to 1.1 mm
[0.020 to 0.043 in.]
Application of sealant
(ThreeBond 1102)