General safety regulations

Attention! Mounting, installation, commissioning and repair of electri-
cal devices has to be carried out only by qualified electricians. The
!
current standards for the installation of door communication systems
must be observed!
When working in systems with 230 V mains voltage, the safety require-
ments according to DIN VDE 0100 must be observed.
When installing TCS:BUS systems, the general safety regulations for
telecommunication systems according to VDE 0800 must be observed:
 separated cabling of heavy and low current lines,
 minimum distance of 10 cm for common cabling,
 use of separators between heavy and low current lines in shared cable
ducts,
 use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm di-
ameter,
 existing lines (modernisation) with deviating cross sections can be used in
compliance with the loop resistance.
Installation – protective measures
With suitable requirements to protect against lightning, it has to be
!
ensured that a voltage of each 32 V DC is not exceeded.
Main door call
4

Safety instructions

Door call from the door with the main serial number (according to
serial number sticker at the device and the package). Main door
calls for front-door stations with ≤ door call AS-border and > door
call AS-border can be realised.