Table 3-1. Signal Descriptions for PCI-DIO-96 and PXI-6508 I/O Connectors (Continued)
Pin
67, 69, 71, 73, 75, 77,
79, 81
68, 70, 72, 74, 76, 78,
80, 82
83, 85, 87, 89, 91, 93,
95, 97
84, 86, 88, 90, 92, 94,
96, 98
This document refers to the ports as A, B, and C and the PPIs (82C55As) as A, B, C, and D. NI-DAQmx, Traditional
NI-DAQ (Legacy), and LabVIEW documentation use numbers to identify each port and PPI. For example, this manual uses
PPI A port A to refer to port A of the 82C55A identified as PPI A. NI-DAQmx, Traditional NI-DAQ (Legacy),
LabWindows/CVI, LabVIEW, or other application software documentation, however, refer to this port as 0. The Alternate
Port ID column shows the correlation between the different port names.
© National Instruments Corporation
Signal Name
CPB<7..0>
DPB<7..0>
CPA<7..0>
DPA<7..0>
3-5
Alternate
Port ID
7
Bidirectional data lines for port B
of PPI C—CPB7 is the MSB,
CPB0 is the LSB.
10
Bidirectional data lines for port B
of PPI D—DPB7 is the MSB,
DPB0 is the LSB.
6
Bidirectional data lines for port A
of PPI C—CPA7 is the MSB,
CPA0 is the LSB.
9
Bidirectional data lines for port A
of PPI D—DPA7 is the MSB,
DPA0 is the LSB.