Operational Modes

1.6.3 Telephone Company Rights and Warnings:
The telephone company, under certain circumstances, may temporarily discontinue services and/or
make changes in its facilities, services, equipment or procedures which may affect the operation of
this digital communicator. However, the telephone company is required to give advance notice of
such changes or interruptions. If the digital communicator causes harm to the telephone network,
the telephone company reserves the right to temporarily discontinue service. Advance notification
will be provided except in cases when advance notice is not practical. In such cases, notification
will be provided as soon as possible. The opportunity will be given to correct any problems and to
file a complaint.
DO NOT CONNECT THIS PRODUCT TO COIN TELEPHONE, GROUND START OR PARTY
LINE SERVICES.
When the digital communicator activates, premise phones will be disconnected.
Two separate phone lines are required. Do not connect both telephone interfaces to the same tele-
phone line.
The digital communicator must be connected to the public switched telephone network upstream of
any private telephone system at the protected premises.
An FCC compliant telephone cord must be used with this equipment. This equipment is designed
to be connected to the telephone network or premises wiring using a compatible RJ31X male mod-
ular plug which is Part 68 compliant.
1.7 Operational Modes
1.7.1 Normal Mode
Normal Mode is the standard mode of operation in which the 411/411UD digital communicator
monitors the host control panel status as well as telephone line voltage and other internal circuits.
In addition to locally annunciating system trouble, active channel and communication fail, the digi-
tal communicator transmits system status information to UL listed central station receivers. Trans-
mitted data includes fire alarm, fire alarm trouble, supervisory alarm and AC loss information.
Specific digital communicator troubles are also transmitted.
1.7.2 Real Time Clock Mode
Real Time Clock Mode allows the user to change the digital communicator's internal 24 hour
clock. Connecting an external Programmer allows access to the various Modes of operation.
While the communicator is in Real Time Clock Mode, it does not monitor channel inputs. Use of
this mode requires a valid password.
1.7.3 Program Mode
Program Mode is used to change the programmed functions of the 411/411UD digital communica-
tor. While the communicator is in Program Mode, it does not monitor channel inputs. Use of this
mode requires a valid password.
1.7.4 Troubleshoot Mode
Troubleshoot Mode may be used for testing the telephone line interconnect wiring. Connection
from the 411/411UD's modular jacks, through the RJ31X jacks and into the telephone network may
be easily checked. In this mode, the Programmer keypad acts similar to a telephone touchpad.
While the communicator is in Troubleshoot Mode, it does not monitor channel inputs.
1.7.5 Default Mode
Default Mode may be used to return all 411/411UD programming back to the factory default set-
tings.
411 & 411UD Manual — P/N LS10105-000GE-E:A 1/29/2014
Product Description
15