Code
Description
0900
Integrated LAN disable error
0901
Integrated LAN enable error
0A00
Display refresh rate error
Problem/Solution
1. Verify the processor module is installed correctly.
Refer to the User's Guide for handling precautions.
2. If the problem persists, the processor module may
need to be replaced.
The system could not disable the integrated LAN.
To correct this:
1. Reset the Integrated LAN by powering off the HP
NetServer.
2. Disconnecting the power cord for 20 seconds.
3. Reconnect the power cord and power on the HP
NetServer.
4. If the error appears upon restarting, update the
system BIOS.
5. Insert the HP Navigator CD-ROM in the CD-ROM
drive and power-cycle your system.
This will initialize the flash utility on HP Navigator
CD-ROM.
6. If the error persists, the system board may need to
be replaced. Contact your service representative.
The system could not enable the integrated LAN.
To correct this:
1. Reset the Integrated LAN by powering off the HP
NetServer.
2. Disconnecting the power cord for 20 seconds.
3. Reconnect the power cord and power on the HP
NetServer.
4. If the error appears upon restarting, update the
system BIOS.
5. Insert the HP Navigator CD-ROM in the CD-ROM
drive and power-cycle your system.
This will initialize the flash utility on HP Navigator
CD-ROM.
6. If the error persists, the system board may need to
be replaced. Contact your service representative.
The parameters returned by the display do not match the
DDC standard used by the NetServer for automatic setup of
ergonomic refresh rates.
To correct this:
1. Disable the 'Plug & Play Display' feature in the Setup
Diagnostics
41