Chapter 4
Code
Description
0400
CD-ROM boot error
0401
CD-ROM drive not
responding
0500
Hard Disk (primary)
controller boot error
Problem/Solution
run the Setup Utility and disable the flexible disk
controller.
2. If the integrated flexible disk controller is needed, the
accessory board's IRQ and address space must be
reconfigured to use other free resources. Refer to the
accessory board installation manual for information.
POST has detected the CD-ROM drive has reported an error
during its self-test.
To correct this:
1. If a CD-ROM disk is present, verify it is correctly
inserted.
2. Verify the CD-ROM drive door or tray has not been
opened or closed during the self-test.
3. Verify all data cables and power cables are firmly
connected.
4. If the problem persists, your CD-ROM drive may
need to be replaced. Contact your service
representative.
POST has detected the CD-ROM drive is not responding, but
is configured in the Setup utility.
To correct this:
1. If the CD-ROM drive has just been removed, press
<F4> to automatically validate the change.
2. Verify all data cables and power cables are firmly
connected.
3. If the cable is damaged, connect the CD-ROM to
another cable, if available. The Setup Utility and the
32-bit disk access driver may need to be modified
accordingly.
4. If the problem persists, your CD-ROM drive may
need to be replaced. Contact your service
representative.
POST has detected a general failure on the integrated
(primary) hard disk controller.
To correct this:
1. Restart your HP NetServer.
2. If the error persists, your system board may need to
be replaced. Contact your service representative.
(The following does not apply to E 800)
1. If no device uses the other IDE channel, connect
your hard disk drive to the other cable to operate with
Diagnostics