HP netserver e 800 Service Manual page 46

Hide thumbs Also See for netserver e 800:
Table of Contents

Advertisement

Chapter 4
Code
Description
0712
DIMM installation error
0713
Incorrect DIMM installed
0800
Cache memory size error
0801
Cache boot error
40
Problem/Solution
either disconnected, or have been replaced by smaller ones.
To correct this:
1. If some main DIMMs have just been removed or
replaced by smaller ones, press <F4> to
automatically validate the change.
2. If no DIMM has been removed or changed, ensure all
DIMMs are properly inserted in the slots.
3. If the problem persists, one of DIMMs may need to
be replaced. Contact your service representative.
POST has detected an incorrectly installed DIMM or the
failure of one or more DIMMs.
To correct this:
1. If additional memory was just installed in your
NetServer, please verify the installation conforms to
the description in the User's Guide.
2. If this error was reported when no additional memory
was just installed, restart the NetServer.
3. If the error persists, contact your service
representative.
POST has detected one or more DIMMs are not the correct
type, or the correct speed.
To correct this:
1. If additional memory was just installed in your
NetServer, please verify the correct DIMM type and
speed for this NetServer was installed. Refer to the
DIMM description in the User's Guide.
2. If this error was reported when no additional memory
was just installed, restart the NetServer.
3. If the error persists, contact your service
representative.
POST has detected the cache memory size is smaller than
previously detected.
To correct this:
1. If the processor module has just been replaced,
press <F4> to automatically validate the change.
2. If the problem persists, the processor module may
need to be replaced.
POST has detected an error in the cache memory module.
To correct this:
Diagnostics