Finish the installation by completely tightening the screws in the same sequence.
c.
If the new system board does not include a system battery, install the one removed from the failed
12.
system board.
Install the power pass-through board.
13.
Install the cable management holder.
14.
Install the Flexible Smart Array P840ar Controller.
15.
If removed, install the internal microSD card.
16.
Install all removed expansion boards on the onboard PCIe expansion slots.
17.
If removed, install the internal USB storage device.
18.
If removed, install the PCI riser cage.
19.
If removed, install the FlexibleLOM blank.
20.
If removed, install the dedicated iLO management module.
21.
If removed, install the rear drive cage and connect the drive backplane cables.
22.
Connect all cables disconnected from the failed system board.
23.
Install the air baffle.
24.
Install the access panel.
25.
Install the server into the rack.
26.
Connect each power cord to the server.
27.
Connect each power cord to the power source.
28.
Press the Power On/Standby button.
29.
The server exits standby mode and applies full power to the system. The system power LED
changes from amber to green.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
After you replace the system board, you must re-enter the server serial number and the product ID.
During the server startup sequence, press the F9 key to access UEFI System Utilities.
1.
Select the System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options
2.
> Advanced System ROM Options > Serial Number, and then press the Enter key.
Enter the serial number and press the Enter key. The following message appears:
3.
Removal and replacement procedures 79