HP 5500 EI Series Configuration Manual page 142

Hide thumbs Also See for 5500 EI Series:
Table of Contents

Advertisement

Step
4.
Configure
threshold
monitoring.
Command
Enable sending traps to the network management server
under specified conditions:
reaction trap { probe-failure consecutive-probe-failures |
test-complete | test-failure cumulate-probe-failures }
Configure a reaction entry for monitoring the probe duration
of a test (not supported in UDP jitter and voice tests):
reaction item-number checked-element probe-duration
threshold-type { accumulate accumulate-occurrences |
average | consecutive consecutive-occurrences }
threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
Configure a reaction entry for monitoring the probe failure
times (not supported in UDP jitter and voice tests):
reaction item-number checked-element probe-fail
threshold-type { accumulate accumulate-occurrences |
consecutive consecutive-occurrences } [ action-type { none |
trap-only } ]
Configure a reaction entry for monitoring packet round-trip
time (only supported in UDP jitter and voice tests):
reaction item-number checked-element rtt threshold-type
{ accumulate accumulate-occurrences | average }
threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
Configure a reaction entry for monitoring the packet loss in
each test (only supported in UDP jitter and voice tests):
reaction item-number checked-element packet-loss
threshold-type accumulate accumulate-occurrences
[ action-type { none | trap-only } ]
Configure a reaction entry for monitoring one-way delay
jitter (only supported in UDP jitter and voice tests):
reaction item-number checked-element { jitter-ds | jitter-sd }
threshold-type { accumulate accumulate-occurrences |
average } threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
Configure a reaction entry for monitoring the one-way delay
(only supported in UDP jitter and voice tests):
reaction item-number checked-element { owd-ds | owd-sd }
threshold-value upper-threshold lower-threshold
Configure a reaction entry for monitoring the ICPIF value
(only supported in voice tests):
reaction item-number checked-element icpif threshold-value
upper-threshold lower-threshold [ action-type { none |
trap-only } ]
Configure a reaction entry for monitoring the MOS value
(only supported in voice tests):
reaction item-number checked-element mos threshold-value
upper-threshold lower-threshold [ action-type { none |
trap-only } ]
132
Remarks
Configure to send
traps.
No traps are sent
to the network
management
server by default.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5500 si series

Table of Contents