Disassembly Procedures
!
Plug Block and Wiring Assembly (Surface
Burner Spark Ignitors)
1. Turn off power to the range.
2. Remove maintop assembly and burner box.
3. Remove plug block mounting bracket mounting
screws.
4. Remove plug block green ground wire from range
frame.
5. Remove storage drawer.
6. Remove screws securing spark module cover box to
storage drawer heat shield.
7. Disconnect wire lead from spark module and remove
plug block and wiring assembly from orifice and plug
block mounting plate.
8. Reverse procedures to reassemble.
Male Loading Plug–Supply Cord
1. Turn off power to the range.
2. Remove storage drawer.
3. Unplug power supply cord from male loading plug.
4. Remove screws securing metal cover box to storage
drawer heat shield located at left bottom section of
range.
5. Depress loading plug spring retaining tabs and push
plug out through opening in the cover box.
Disconnect wires from male loading plug.
6. Reverse procedures to reassemble.

Power Supply Cord

1. Turn off power to the range.
2. Remove storage drawer.
3. Unplug power cord from wall outlet and from loading
plug mounted in side of the cover box.
4. Remove supply cord strain relief clamp and remove
cord.
5. Reverse procedures to reassemble.

Blower/Fan Cutout Relay

1. Turn off power to the range.
2. Remove storage drawer.
3. Remove screws securing metal cover box to storage
drawer heat shield located at right front bottom
section of the range.
4. Disconnect blower relay wire leads. Label leads for
correct replacement during reassembly.
5. Remove blower relay mounting screws and locknuts
and remove relay.
6. Reverse procedures to reassemble.
RS2310003 Rev. 0
WARNING
Unplug power source and shut off gas suppl before servicing,
unless testing requires it.

Blower Motor (XPH100 Blower Kit)

1. Turn off power to the range
2. Turn off and disconnect gas supply to the range.
3. Disconnect downdraft ductwork from range and
remove range from cabinet.
4. Remove right side front trim and right side panel.
5. Remove storage drawer.
6. Disconnect three wire (120 VAC supply) terminal
block on right side of blower motor.
7. Remove screws securing motor assembly to blower
box top and rear plenum.
8. Raise the rear of the range enough to remove motor
assembly.
9. Transfer galvanized blower box bottom to new blower
motor.
NOTE: Capacitor is supplied with new blower motor. A
replacement capacitor is available by ordering
part number D6711804.
10.Reverse procedures to reassemble. Be certain to
check gas connection with liquid leak detector.