Installation Instructions
Newer Anti-tip Bracket
To reduce risk of range tipping, secure range with a
properly installed anti-tip bracket.
1. Measure 3
1
/
inches from back wall on right and left
2
side of cabinet cutout. Mark measurements on floor
and draw a straight line connecting marks.
2. Position anti-tip bracket.
• If range is installed beside cabinet(s), place anti-
tip bracket with back edge on line drawn on floor
and side of bracket against cabinet.
• If range is not installed beside cabinet(s), position
range where it will be installed. Draw a line along
side of range on floor from front to back. Remove
range. Place anti-tip bracket with back edge over
line drawn 3
1
/
inches from back wall and side of
2
bracket over line drawn along side of range on
floor.
• Anti-tip bracket can be installed on either right or
left side.
3. Mark 2 hole locations in anti-tip bracket.
4. Drill 2 holes.
• If drilling into wood, use a
• If drilling into concrete, use a
bit and insert plastic anchors.
5.
Secure bracket to floor using screws supplied.
6.
Slide range into position.
7.
Remove range storage drawer and confirm anti-
tip bracket is engaged with range leveling leg.

Electrical Connection Requirements

!
WARNING
To avoid the risk of serious electrical shock or
property damage, do not cut or remove the third
(ground) prong from the power plug. A 3- wire
grounded conductor system must be used. Relying
on the flexible connector, hard piping or any other part
of the gas supply line as a ground may cause fire,
electrical shock and/or erratic control operation.
3 1/2"
or
3
/
inch drill bit.
32
3
/
inch masonry drill
16
Range must be electrically grounded in accordance with
local codes or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA No. 70-Latest
Edition. In Canada, electrical connections are to made in
accordance with CSA C22.1 Canadian Electrical Code.
Use a 120 volt, 60 hertz 3 prong receptacle protected by
a 15 amp circuit breaker or time delay fuse.
A qualified electrician should confirm the outlet is
properly grounded.
If a 2 -prong outlet is encountered, range owner must
replace outlet before using range. Do not cut off cord or
remove grounding plug.
Range wiring diagram is located on the bottom of the
storage drawer.

Electrical Connection Clearance

Electrical connection must be located in the shaded area
shown in Figure below. Electrical connection must not
interfere with gas connection.
3 1/2"
12 1/4"
9 1/2"

Gas Connection Requirements

!
Range designed for use with natural gas only.
Before connecting this appliance to the gas supply piping
system, confirm that installation meets the requirements
of local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1-Latest Edition. In
Canada installation must conform with local codes or the
current Natural Gas Installation Code CAN/CGA-B149.1.
11
14 3/4"
30 1/8"
CAUTION
RS2310003 Rev. 1