Anti-Tip Bracket Installation; Electrical Connection Requirements; Electrical Connection Clearance - Amana AGDS901 Owner's Manual

Self-cleaning gas downdraft range
Hide thumbs Also See for AGDS901:
Table of Contents

Advertisement

CC30 Wall Cap with Flap = 7
(available from dealer)

Anti-tip Bracket Installation

To reduce risk of range tipping, secure range with a
properly installed anti-tip devise packed with range.
1. Measure 5
1
/
inches from back wall on right and left
8
side of cabinet cutout. Mark measurements on floor
and draw a straight line connecting marks.
2. Position anti-tip bracket.
• If range is installed beside cabinet(s), place anti-tip
bracket with inside edge over line drawn on floor
and end of bracket against cabinet.
• If range is not installed beside cabinet(s), position
range where it will be installed. Draw a line along
side of range on floor from front to back. Remove
range. Place anti-tip bracket with inside edge over
line drawn 5
1
/
inches from back wall and end of
8
bracket over line drawn along side of range on floor.
• Anti-tip bracket can be installed on either right or
left side.
3. Mark 2 hole locations in anti-tip bracket.
4. Drill 2 holes.
• If drilling into wood, use a
• If drilling into concrete, use a
bit and insert plastic anchors.
5. Secure bracket to floor using screws supplied.
1
/
Ft.
2
3
/
inch drill bit.
32
3
/
inch masonry drill
16

Electrical Connection Requirements

WARNING
To avoid the risk of serious electrical shock or
property damage, do not cut or remove the third
(ground) prong from the power plug. A 3- wire
grounded conductor system must be used. Relying
on the flexible connector, hard piping or any other part
of the gas supply line as a ground may cause fire,
electrical shock and/or erratic control operation.
Range must be electrically grounded in accordance with
local codes or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA No. 70-Latest
Edition. In Canada, electrical connections are to made in
accordance with CSA C22.1 Canadian Electrical Code.
Use a 120 volt, 60 hertz 3 prong receptacle protected by
a 15 amp circuit breaker or time delay fuse.
A qualified electrician should confirm the outlet is
properly grounded.
If a 2 -prong outlet is encountered, range owner must
replace outlet before using range. Do not cut off cord or
remove grounding plug.
Range wiring diagram is located on the bottom of the
storage drawer.

Electrical Connection Clearance

Electrical connection must be located in the shaded area
shown in Figure below. Electrical connection must not
interfere with gas connection.
5"
8
5"
18"
10"