Shipping And Packing List; Safety Information - Lennox G61MPVT-36B-070 Installation Instructions Manual

Table of Contents

Advertisement

G61MPVT Gas Furnace
The G61MPVT gas furnace is equipped with a two−stage,
variable speed integrated control. This control ensures
compatibility with a thermostat which provides humidity
control. Each G61MPVT is shipped ready for installation
in the upflow, downflow, horizontal left air discharge or
horizontal right air discharge position. The furnace is
shipped with the bottom panel in place. The bottom panel
must be removed if the unit is to be installed in upflow ap-
plications with bottom return air. The bottom panel must
also be removed and discarded in all downflow or horizon-
tal applications.
The furnace is equipped for installation in natural gas ap-
plications. A conversion kit (ordered separately) is re-
quired for use in propane/LP gas applications.
All G61MPVT models can be installed as a Direct Vent
gas central furnace. G61MPVT−070, −090 and −110 mod-
els can be installed as a Non−Direct Vent gas central fur-
nace.
NOTE − In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors. In
Non−Direct Vent installations, combustion air is taken from
indoors and flue gases are discharged outdoors. See figure
2 for applications involving roof termination.
DIRECT VENT INSTALLATION
COMBUSTION
EXHAUST
AIR INTAKE
OUTLET
OUTSIDE OF
HOUSE
G61MPVT
CONDENSATE
DRAIN
FIGURE 2
NON−DIRECT VENT
INSTALLATION
EXHAUST
OUTLET
COMBUSTION
AIR INTAKE INSIDE
OF HOUSE
G61MPVT
CONDENSATE
DRAIN
Page 4

Shipping and Packing List

Package 1 of 1 contains
1 − Assembled G61MPVT unit
1 − Bag assembly containing the following:
3 − Screws
3 − Wire nuts
1 − Snap bushing
1 − Snap plug
1 − Wire tie
1 − Condensate trap
1 − Condensate trap cap
2 − 2" diameter vent / intake plugs
1 − 3" diameter cabinet plug (intake)
2 − 2" diameter debris screen
1 − Bag assembly containing the following:
1− 50 hertz power wiring harness
NOTE − G61MPVT−60C−110 and −60D−135 units also in-
clude two 50mm to 80mm diameter ABS street elbows and
two 80mm to 50mm ABS reducing elbows, which are
shipped on the blower deck in the heating compartment.
The following items may also be ordered separately:
1 − Thermostat
1 − Propane/LP changeover kit
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.

Safety Information

WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a qualified installer, service agency
or the gas supplier.
CAUTION
As with any mechanical equipment, personal injury
can result from contact with sharp sheet metal
edges. Be careful when you handle this equipment.

Advertisement

Table of Contents
loading

This manual is also suitable for:

G61mpvt-60c-090G61mpvt-60c-110G61mpvt-60d-135

Table of Contents