Lennox G61MPVT-36B-070 Installation Instructions Manual page 50

Table of Contents

Advertisement

Troubleshooting: Continuous Fan Sequence of Operation
CONTINUOUS LOW SPEED FAN SEQUENCE OF OPERATION
MANUAL FAN SELECTION MADE AT THERMOSTAT.
AFTER 2 SECOND DELAY, INDOOR BLOWER IS
ENERGIZED ON CONTINUOUS FAN SPEED.
YES
YES
THERMOSTAT CALLS FOR FIRST STAGE COOL.
THERMOSTAT CALLS FOR FIRST−STAGE HEAT.
YES
YES
INDOOR BLOWER RAMPS TO FIRST STAGE
AFTER 45−SECOND DELAY, INDOOR BLOWER
COOLING SPEED AFTER A 2−SECOND DELAY.
SWITCHES TO LOW HEAT SPEED.
FIRST−STAGE COOL DEMAND SATISFIED?
FIRST−STAGE HEAT DEMAND SATISFIED.
YES
YES
NO
NO
SECOND STAGE COOL DEMAND
THERMOSTAT CALLS FOR SECOND−STAGE HEAT.
YES
INDOOR BLOWER RAMPS TO SECOND
INDOOR BLOWER SWITCHES TO HIGH HEAT SPEED
STAGE COOL SPEED
AFTER 30−SECONDS.
YES
SECOND STAGE COOL DEMAND SATISFIED?
SECOND−STAGE HEAT DEMAND SATISFIED.
YES
YES
INDOOR BLOWER RAMPS DOWN TO FIRST STAGE
INDOOR BLOWER RAMPS DOWN TO LOW
COOL SPEED.
HEAT SPEED.
Page 50

Advertisement

Table of Contents
loading

This manual is also suitable for:

G61mpvt-60c-090G61mpvt-60c-110G61mpvt-60d-135

Table of Contents