Gas Furnace; Shipping And Packing List; Safety Information - Lennox A97DF2E Installation Instructions Manual

Warm air gas furnace downflow air discharge direct vent & non-direct vent
Table of Contents

Advertisement

Gas Furnace

This Category IV gas furnace is shipped ready for
installation in the downflow position.
The furnace is equipped for installation in natural gas
applications. A conversion kit (ordered separately) is
required for use in LP/propane gas applications.
This unit can be installed as either a Direct Vent or a Non-
Direct Vent gas central furnace.
NOTE: In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors.
Non-Direct Vent installations, combustion air is taken from
indoors or ventilated attic or crawl space and flue gases
are discharged outdoors. See Figure 2 and Figure 3 for
application involving roof termination.
Figure 2.
Figure 3.
Page 4 of 52

Shipping and Packing List

Package 1 of 1 contains:
1 - Assembled Gas Unit
1 - Bag assembly containing the following:
1 - Snap bushing
1 - Snap Plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap clamp
1 - 2" diameter debris screen
1 - 3/4" Threaded street elbow
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
Please refer to specification sheets for available
accessories.

Safety Information

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
DANGER OF EXPLOSION!
There are circumstances in which odorant used with
LP/propane gas can lose its scent. In case of a leak,
LP/propane gas will settle close to the floor and may be
difficult to smell. An LP/propane leak detector should be
installed in all LP applications.
Issue 2327
WARNING
CAUTION
DANGER
508391-01