Gas Furnace

A97UH2E & 97G2UHE Category IV gas furnace are
shipped ready for installation in the upflow or horizontal
position. The furnace is shipped with the bottom panel in
place. The bottom panel must be removed if the unit is to
be installed in horizontal or upflow applications with bottom
return air.
The A97UH2E & 97G2UHE can be installed as either a
Direct Vent or a Non-Direct Vent Gas Central Furnace.
Exception: A97UH2E030XE24B and 97G2UH030BE08
are direct vent only.
The furnace is equipped for installation in natural gas
applications. A conversion kit (ordered separately) is
required for use in propane/LP gas applications.
NOTE: In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors.
Non-Direct Vent installations, combustion air is taken from
indoors or a ventilated attic or crawl space and flue gases
are discharged outdoors. See Figure 2 and Figure 3 for
applications involving roof termination.
Figure 2.
Figure 3.
Page 4 of 60

Shipping and Packing List

1 - Assembled Gas Furnace
1 - Bag assembly containing the following:
1 - Snap bushing
1 - Snap Plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap clamp
1 - 2" Diameter debris screen
1 - 3/4" Threaded street elbow
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
Please refer to specification sheets for available
accessories.

Safety Information

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
DANGER OF EXPLOSION!
There are circumstances in which odorant used with
LP/Propane gas can lose its scent. In case of a leak,
LP/Propane gas will settle close to the floor and may be
difficult to smell. An LP/Propane leak detector should be
installed in all LP applications.
Use only the type of gas approved for use with this furnace.
Refer to unit nameplate.
A97UH2E & 97G2UHE units are CSA International certified
to ANSI Z21.47 and CSA 2.3 standards.
Issue 2327
WARNING
CAUTION
DANGER
508390-01