Lennox G61MPVT-36B-070 Installation Instructions Manual page 29

Table of Contents

Advertisement

100% CFM
OFF
DEMAND
Ramping Option D
S Motor runs at 100% until demand is satisfied.
S Once demand is met, motor ramps down to stop.
100% CFM
OFF
COOLING
DEMAND
G61MPVT−36B−070 BLOWER MOTOR PERFORMANCE (LESS FILTER)
0.0" to 0.8" w.g. (0 through 200 Pa) External Static Pressure Range
Factory Settings: Heating Speed − 2; Cooling Speed − 4; Speed Adjust − NORM
ADJUST"
Switch
1
Positions
cfm
+
895
NORM
820
N/A
ADJUST"
1
Switch
Positions
cfm
+
820
NORM
760
N/A
N/A − First and second stage HEAT positions shown cannot be used on this model.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s).
100% CFM
45 SEC.
OFF
Second Stage HEAT" Speed
2
3
L/s
cfm
L/s
cfm
420
1025
485
1290
385
940
445
1155
N/A
840
395
1020
First Stage HEAT" Speed
2
3
L/s
cfm
L/s
cfm
385
930
440
1160
360
865
410
1045
N/A
775
365
930
Switches 7 and 8 −− Heating Mode Blower Speed −−
OFF
Switches 7 and 8 are used to select heating mode blower
motor speed. The unit is shipped from the factory with the
dip switches positioned for medium low (2) speed indoor
blower motor operation during the heating mode. The table
below provides the heating mode blower speeds that will
result from different switch settings. Refer to tables 14
through NO TAG for corresponding L/s values.
Heating Mode Blower Speeds
Speed
1 − Low
2 − Medium Low
(Factory)
3 − Medium High
4 − High
TABLE 14
Speed Switch Positions
4
1
L/s
cfm
L/s
cfm
610
1340
630
1015
545
1210
570
930
480
1055
495
830
4
1
L/s
cfm
L/s
cfm
550
1210
570
730
495
1090
515
680
440
965
455
625
Page 29
TABLE 13
Switch 7
On
Off
On
Off
Second Stage COOL" Speed
2
3
L/s
cfm
L/s
cfm
480
1190
560
1280
440
1065
505
1155
390
950
450
1010
First Stage COOL" Speed
2
3
L/s
cfm
L/s
cfm
345
815
385
865
320
755
355
795
295
695
330
730
Switch 8
On
On
Off
Off
4
L/s
cfm
L/s
605
1395
660
545
1270
600
475
1105
520
4
L/s
cfm
L/s
410
935
440
375
855
405
345
775
365