SLP99UHV Gas Furnace

The SLP99UHV category IV gas furnace is equipped with
a variable-capacity, variable-speed integrated control.
This control ensures compatibility with a communicating
thermostat, the iHarmony
mostat which provides humidity control. Each SLP99UHV
is shipped ready for installation in the upflow, horizontal
left air discharge or horizontal right air discharge position.
The furnace is equipped for natural gas applications only.
A changeover kit may be ordered for LP applications.
The SLP99UHV must be installed only as a Direct Vent
gas furnace.
NOTE - In Direct Vent installations, combustion air is tak-
en from outdoors and flue gases are discharged outdoors.
See FIGURE 2 for applications including roof termination.
DIRECT VENT INSTALLATION
COMBUSTION
AIR INTAKE
OUTSIDE OF
HOUSE
FIGURE 2

Shipping and Packing List

Package 1 of 1 contains
1 - Assembled SLP99UHV unit
1 - Bag assembly containing the following:
1 - Snap bushing
1 - Snap plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap cap clamp
1 - 3/4" Threaded street elbow
1 -Flue Coupling
1- Bag containing discharge air sensor
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
The following items may also be ordered separately:
1 - Thermostat
1 - Natural to LP gas conversion kit
1 - High altitude kit
1 - Horizontal suspension kit
zone control system, or a ther-
®
EXHAUST OUTLET
Danger of explosion.
There are circumstances in which odorant used with LP/
propane gas can lose its scent. In case of a leak, LP/
propane gas will settle close to the floor and may be
difficult to smell. An LP/propane leak detector should be
installed in all LP applications.

Safety Information

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves
and protective clothing.
Use only the type of gas approved for use with this fur-
nace. Refer to unit nameplate.
Building Codes
In the USA, installation of gas furnaces must conform with
local building codes. In the absence of local codes, units
must be installed according to the current National Fuel
Gas Code (ANSI-Z223.1/NFPA 54). The National Fuel
Gas Code is available from the following address:
American National Standards Institute, Inc.
11 West 42nd Street
New York, NY 10036
Installed Locations
In Canada, installation must conform with current National
Standard of Canada CSA-B149 Natural Gas and Propane
Installation Codes, local plumbing or waste water codes
and other applicable local codes.
This furnace is designed for installation clearances to
combustiblematerial as listed on the unit nameplate and
in the tables in FIGURE 10 and FIGURE 11. Accessibility
and service clearances must take precedence over fire
protection clearances.
NOTE - For installation on combustible floors, the furnace
shall not be installed directly on carpeting, tile, or other
combustible material other than wood flooring.
For installation in a residential garage, the furnace must
be installed so that the burner(s) and the ignition source
are located no less than 18 inches (457 mm) above the
floor. The furnace must be located or protected to avoid
physical damage by vehicles. When a furnace is installed
Page 4
DANGER
WARNING
CAUTION