Invacare® TDX SP2® Series
Tools:
•
11 mm jaw spanner
•
Slotted screwdriver
80
1.
Remove the side-mounted legrests if fitted. A centrally-fitted,
manually adjustable legrest should be put in its top position by
turning the spindle A.
2.
Remove the thumb screws securing the front shroud/battery
retention bracket to the wheelchair A.
3.
Lift up to unhook the battery retention bracket from the
wheelchair frame and remove the front shroud/battery retention
bracket from the wheelchair.
1578997-C