If Remote Controller Signal Does Not Reach Other Components; Using An External Device With 12V Trigger; Terminal - Onkyo TX-NR1000 Instruction Manual

Onkyo home stereo system owner's manual
Hide thumbs Also See for TX-NR1000:
Table of Contents

Advertisement

Connecting Components not
Reached by the Remote Controller
Signals (IR IN/OUT) —Continued
If Remote Controller Signal Does not
Reach Other Components
Effective Sensor Layout
In this situation, you will need to use a commercially
available IR emitter. Connect the mini plug of the IR
emitter to the IR OUT terminal on the TX-NR1000/
TX-NR5000E and then place the IR emitter on the
remote sensor of the component or facing it. When the
IR emitter is connected, only the signal input to the IR
IN terminal is output to the IR OUT terminal. The sig-
nal input from the remote sensor on the front of the
TX-NR1000/TX-NR5000E will not be output to the IR
OUT terminal.
Connecting
block
IR IN
TX-NR1000/
TX-NR5000E
IR OUT
IR Emitter
Other
component
Making Sensor Connections
When you place the IR receiver in the main room, con-
nect the cable from the connecting block to the IR OUT
MAIN terminal. When you place the IR receiver in the
remote zone, connect the cable from the connecting
block to the ZONE 2 or ZONE 3 terminal accordingly.
: Signal flow
Mini plug
IR Emitter
MAIN
ZONE 2
ZONE 3
IN
OUT
IR
TX-NR1000/TX-NR5000E
46
IR Receiver
Remote controller
: Signal flow
Other component
Remote control
sensor
Emitter
Using an External
Device with 12V Trigger

Terminal

You can automatically turn on the connected AV com-
ponents with the output signal from the TX-NR1000/
TX-NR5000E's 12V TRIGGER OUT terminal.
Making a Connection
Connect the 12V TRIGGER OUT terminal on the
TX-NR1000/TX-NR5000E to the 12V TRIGGER IN
terminal on other components. Every 12V TRIGGER
OUT terminal can be connected to the components
whether they are placed in the main room, Zone 2, or
Zone 3.
The TX-NR1000/TX-NR5000E has five 12V TRIG-
GER OUT terminals and the maximum currents to be
connected are as follows:
A: 200 mA
B, C, D and E: 100 mA
After making connections, configure the association
between the room (zone) and the component to be
turned on (Refer to "12V Trigger Assign" under "Input
Setup" on page 98).
Device A
12V TRIGGER
IN
200mA MAX.
Device B
12V TRIGGER
IN
100mA MAX.
Device C
12V TRIGGER
IN
100mA MAX.
Device D
12V TRIGGER
IN
100mA MAX.
Device E
12V TRIGGER
IN
100mA MAX.
12V
TRIGGER
OUT
A
200mA MAX.
B
100mA MAX.
C
100mA MAX.
D
100mA MAX.
E
100mA MAX.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tx-nr5000e

Table of Contents