Checking the High Flow
Hydraulic-Fluid Level
TC Models Only
Service Interval: Before each use or daily (check the level of
hydraulic fluid before the engine is first
started, and daily thereafter)
Hydraulic-fluid type: Toro Premium All Season
Hydraulic Fluid (Available in 5 gallon pails or 55 gallon
drums. See parts catalog or Toro distributor for part
numbers.)
Alternate fluids: If the Toro fluid is not available, another
conventional petroleum–based fluid may be used provided
it meets the following material properties and industry
specifications. Consult with your lubricant distributor to
identify a satisfactory product.
Note: Toro will not assume responsibility for damage
caused by improper substitutions, so use only products
from reputable manufacturers who will stand behind their
recommendation.
High Viscosity Index/Low Pour Point Antiwear
Hydraulic Fluid, ISO VG 46
Material Properties:
Viscosity—ASTM D445 cSt @ 40ºC: 44 to 48/cSt @
100ºC: 7.9 to 8.5
Viscosity Index, ASTM D2270—140 to 152
Pour Point, ASTM D97— -35ºF to -46ºF
FZG, Fail stage—11 or better
Water content (new fluid)—500 ppm (maximum)
Industry Specifications:
Vickers I-286-S, Vickers M-2950-S, Denison HF-0, Vickers
35 VQ 25 (Eaton ATS373-C)
1. Clean the area around the filler neck and the cap of the
hydraulic tank
(Figure
2. Remove the cap from the filler neck.
1. Cap
20).
Figure 20
3. Remove the dipstick
and wipe it with a clean rag.
4. Insert the dipstick into the filler neck, then remove it
and check the fluid level.
Note: The fluid level should be between the 2 marks
on the dipstick.
5. If the level is low, add the appropriate fluid to raise
the level to the upper mark; refer to
High-Flow Hydraulic Fluid and Filter (page
6. Install the dipstick and cap onto the filler neck.
7. Start the engine and turn on the attachment.
Note: Let them run for about 2 minutes to purge air
from the system.
Important: The machine must be running before
starting the high-flow hydraulics.
8. Shut off the engine and attachment and check for leaks.
WARNING
Hydraulic fluid escaping under pressure can
penetrate skin and cause injury.
• Make sure that all hydraulic fluid hoses
and lines are in good condition and all
hydraulic connections and fittings are tight
before applying pressure to the hydraulic
system.
• Keep your body and hands away from
pinhole leaks or nozzles that eject
high-pressure hydraulic fluid.
• Use cardboard or paper to find hydraulic
leaks.
• Safely relieve all pressure in the hydraulic
system before performing any work on the
hydraulic system.
• Seek immediate medical attention if fluid
is injected into your skin.
24