12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
▲▲▲
▲ ▲▲▲
▲ ▲▲▲
6. Install:
• Battery
7. Connect:
• Battery leads
(to the battery terminals)
ECA13630
NOTICE
First, connect the positive battery lead "1",
and then the negative battery lead "2".
8. Check:
• Battery terminals
Dirt → Clean with a wire brush.
Loose connection → Connect properly.
9. Lubricate:
• Battery terminals
Recommended lubricant
Dielectric grease
10.Install:
• Right upper inner panel
Refer to "GENERAL CHASSIS" on page 4-1.
EAS28040
CHECKING THE RELAYS
Check each switch for continuity with the pocket
tester. If the continuity reading is incorrect, re-
place the relay.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
1. Disconnect the relay from the wire harness.
2. Connect the pocket tester (Ω × 1) and battery
(12 V) to the relay terminals as shown.
Check the relay operation.
Out of specification → Replace.
▲ ▲▲▲
▲ ▲▲▲
▲ ▲▲▲
1
2
ELECTRICAL COMPONENTS
Starter relay
R
▲▲▲
B
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Relay unit (starting circuit cut-off relay)
Br/W
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
8-177
3
1
2
4
Continuity
(between "3" and "4")
B/Y
Continuity
(between "3" and "4")
R