ZONE OPTI ON S - ZONE S 49 T O 64 (AD DRESS 1285-1400)
ZONE OPTIONS
ZN64 ZN63 ZN62 ZN61
Priority
Priority with Bypass
Auto-Bypass
Selective Bypass
Keyswitch Arming
Auto-Bypass Re-entry
Pre-Alarm Warning
Never Arm
24-Hour Zone
Alarm Output
Pulsed Alarm Output
PGM1 Output
PGM2 Output
Entry/Exit 1
Entry/Exit 2
Exit/Entry Follower
Auto Reset
Swinger Shutdown
Chime
Abort Delay
Power-up Delay
Day Zone Open
Day Zone Short
Alarm on Day Zone
Alarm Telco 1
Alarm Restore 1
Trouble Telco 1
Trouble Restore 1
Alarm Telco 3
Alarm Restore 3
Trouble Telco 3
Trouble Restore 3
No EOL Resistor
Trouble on Open
Trouble on Short
Zone Area 1
Zone Area 2
Zone Area 3
Zone Area 4
Interior (Stay) Bypass
Keypad Sounder on Alarm
Fire (C)
Fire Alarm Verification
(C)
Zone ANDing Group 1
Zone ANDing Group 2
Zone ANDing Group 3
Zone ANDing Group 4
Sensor Watch
RESERVED
Chime 2
See Steps listed at
bottom of page 44
Step 1
When the Easy Program Menu is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
NOTES:
(A) 50ms Loop Response only available for zones 1-8.
(B) 2-wire Smoke Detectors only available for zones 7 & 8, and Fire must also be selected.
(C) If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Mode.
--Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown and Zone Area 1 are enabled for the total number of zones entered in "# OF ZONES IN AREA1 ENTER # ZONES".
--Alarm Telco 1 is enabled for the zone number(s) entered in "REPORT ALL ZONES TO CENTRAL ZONES? Y/N".
--Entry/Exit 1 and Chime are enabled for the zone number(s) entered in "ENTRY/EXIT ZONES ENTER ZONE #".
--Exit/Entry Follower and Interior Bypass are enabled for the zone number(s) entered in "INTERIOR ZONES ENTER ZONE #".
--Pulse Alarm Output is enabled for the zone number(s) entered in "FIRE ZONES ENTER ZONE #" or "2-WIRE FIRE ZNS ENTER ZONE #".
--Fire is enabled for the zone number(s) entered in "FIRE ZONES ENTER ZONE #".
--2-Wire Smoke Detector is enabled for the zone number(s) entered in "2-WIRE FIRE ZNS ENTER ZONE #".
X
GEM-P1664EX Programming Instructions
ZONES 61-64
LEFT DATA VALUES
ADDRESS
)
(CIRCLE
L ADDR R
8
4
2
1
1349
8
4
2
1
1350
8
4
2
1
1351
8
4
2
1
1352
8
4
2
1
1353
8
4
2
1
1354
8
4
2
1
1355
8
4
2
1
1356
8
4
2
1
1357
8
4
2
1
1358
8
4
2
1
1359
8
4
2
1
1360
8
4
2
1
1361
8
4
2
1
1362
8
4
2
1
1363
8
4
2
1
1364
8
4
2
1
1365
8
4
2
1
1366
8
4
2
1
1367
8
4
2
1
1368
8
4
2
1
1369
8
4
2
1
1370
8
4
2
1
1371
8
4
2
1
1372
8
4
2
1
1373
8
4
2
1
1374
8
4
2
1
1375
8
4
2
1
1376
8
4
2
1
1377
8
4
2
1
1378
8
4
2
1
1379
8
4
2
1
1380
8
4
2
1
1381
8
4
2
1
1382
8
4
2
1
1383
8
4
2
1
1384
8
4
2
1
1385
8
4
2
1
1386
8
4
2
1
1387
8
4
2
1
1388
8
4
2
1
1389
8
4
2
1
1391
8
4
2
1
1392
8
4
2
1
1394
8
4
2
1
1395
8
4
2
1
1396
8
4
2
1
1397
8
4
2
1
1398
8
4
2
1
1399
8
4
2
1
1400
Step 2
Step 4
Step 4
ZONES 57-60
ZONES 53-56
RIGHT DATA VALUES
LEFT DATA VALUES
)
(CIRCLE
(CIRCLE
ZN60 ZN59 ZN58 ZN57 ZN56 ZN55 ZN54 ZN53
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
8
4
2
1
8
4
Step 2
Step 2
WI1387 7/05
ZONES 49-52
ADDRESS
RIGHT DATA VALUES
)
(CIRCLE
L
ADDR R
ZN52 ZN51 ZN50 ZN49
2
1
1285
8
2
1
1286
8
2
1
1287
8
2
1
1288
8
2
1
1289
8
2
1
1290
8
2
1
1291
8
2
1
1292
8
2
1
1293
8
2
1
1294
8
2
1
1295
8
2
1
1296
8
2
1
1297
8
2
1
1298
8
2
1
1299
8
2
1
1300
8
2
1
1301
8
2
1
1302
8
2
1
1303
8
2
1
1304
8
2
1
1305
8
2
1
1306
8
2
1
1307
8
2
1
1308
8
2
1
1309
8
2
1
1310
8
2
1
1311
8
2
1
1312
8
2
1
1313
8
2
1
1314
8
2
1
1315
8
2
1
1316
8
2
1
1317
8
2
1
1318
8
2
1
1319
8
2
1
1320
8
2
1
1321
8
2
1
1322
8
2
1
1323
8
2
1
1324
8
2
1
1325
8
2
1
1327
8
2
1
1328
8
2
1
1330
8
2
1
1331
8
2
1
1332
8
2
1
1333
8
2
1
1334
8
2
1
1335
8
2
1
1336
8
Step 4
Step 4
Step 2
L
NAPCO Security Systems
)
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1
4
2
1

Advertisement

Table of Contents
loading

Table of Contents