7.1.2 Safety Conditions

The building where the OfficeServ 7030 system is installed should have lightning rods and
groundings to protect the system from lightning and electric leakage.
Check if the OfficeServ 7030 system is not inclined and is in level position.
Do not place devices that may cause electromagnetic interference near the system.
Place a fire extinguisher near the system.
Check if the AC voltage switch of the PSU is properly set to 110VAC power.
Check if the grounding terminal on the rear panel of the system is properly connected to
the external grounding.

7.2 Starting the System

It is required to clear memory and start with a default database when using the OfficeServ
7030 system. The system does not have a battery switch to clear memory. The system memory
is cleared to default by the performing the following procedure:
1) Check if the cards and cables are properly mounted and connected to the OfficeServ
7030.
2) To start system from default (Clear memory): Power up the system and let the system
begin to boot.
3) About 10 seconds into the bootup sequence, press in the RST (reset) switch on the front
of the 7030 main unit.
4) Hold in the RST switch for approximately 7 to 10 seconds (this will default the database).
5) Release the RST switch and wait for system to complete the boot up process. Check the
LEDs of the OfficeServ 7030.
6) The RUN LED of the OfficeServ 7030 main unit lights green and the MC LED flashes when
the system normally starts the booting process.
7) Once the booting is completed, the RUN LED of the 7030 flashes green, and the MC LED
stops flashing and remains lit (approximately 3 minutes).
8) When the system completes the bootup, the system memory is cleared and the
database is at default.
9) Enable voice mail and/or MGI channels by entering the appropriate license key in system
programming (if voice mail or MGI services are required).
10) Test system for normal operation.