Samsung OfficeServ 7030 Installation Manual page 11

Hide thumbs Also See for OfficeServ 7030:
Table of Contents

Advertisement

OfficeServ 7030
TECHNICAL MANUAL
Telephone line cord
To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG), UL Listed or CSA
Certified Telecommunication Line Cord.
Prohibition of metal accessories
Do not wear metal accessories such as rings and watches to prevent electric damages to the
system.
AC power connection restriction
Do not share the AC power of the OfficeServ 7030 system or the AC power of the external UPS
with other devices.
Checking MEM LED before power off
Don't turn off the power during blinking MEM LED. It may cause malfunction of system. If you
want to turn off power, turn off power switch after dismounting MEM with 'Key MMC 817 STOP
MEMORY'.
Checking power-off
Check if the cabinet power is turned off when mounting the board. Inserting or removing a
board while the power is turned on may damage the board.
Board reset
New settings are applied only after the board is reset. The system may malfunction if the board
is not properly initialized.
Caution for Installation
Only a trained service staff may install the OfficeServ 7030 system.
Turning off power switch after dismounting MEM
You should dismount MEM before turning off power switch. Use 'Key MMC 817 MEM UMOUNT'
when dismounting MEM.
INTRODUCTION MAY 2010
xi