WOLF SEALED BURNER RANGETOPS
Planning Information
The platform to support the sealed burner rangetop must
include a cut-out for electrical and gas supply connections.
Refer to the chart below for minimum base support.
When installing against a combustible surface, a minimum
5"
riser is required for model SRT366, and a minimum
(127)
10"
riser is required for 36" and 48" sealed burner
(254)
rangetops with a charbroiler or griddle. Follow all minimum
clearances to combustible surfaces shown in the illustration
on the following page.
A Wolf pro ventilation hood is recommended with the sealed
burner rangetop. If the rangetop is to be installed without
minimum clearance, 44"
ventilation, a 36"
(914)
charbroiler, from countertop to combustible materials
above the rangetop is required. Refer to page 120 for pro
ventilation.
A downdraft can be used with models SRT304 and SRT366.
An accessory trim kit is necessary for this installation. Con-
tact an authorized Wolf dealer for details.
INSTALLATION REQUIREMENTS
PLATFORM
Thickness
BASE SUPPORT
30" Rangetop
36" Rangetop
48" Rangetop
|
98
Wolf Customer Care 800.222.7820
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration on the following page. A separate circuit,
servicing only this appliance is required.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
Power Cord
for
(1118)
GAS SUPPLY
A gas supply line of
the rangetop. If local codes permit, a certified, 3'
1
/
"
or
(13)
2
recommended to connect the units
the gas supply line.
Wolf natural gas rangetops will function up to 10,250'
3
/
"
(19)
4
in altitude without adjustment and LP gas ran-
(3124 m)
getops up to 8,600'
MIN
200 lb
these elevations, contact an authorized Wolf dealer for a
(91 kg)
250 lb
(113 kg)
high altitude conversion kit.
300 lb
(136 kg)
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
grounded, 110/120 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
3
/
"
rigid pipe must be provided to
(19)
4
3
/
"
ID flexible metal appliance connector is
(19)
4
1
/
" NPT female inlet to
2
. If the installation exceeds
(2621 m)
14"
(34.9 mb)
14"
(34.9 mb)
6'
(1.8 m)
long,
(.9 m)
WC
5"
(12.5 mb)
7"
(17.5 mb)
, .5 psi
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
, .5 psi
(3.5 kPa)