Download Print this page

Wolf SO27TM/S/TH Design Manual page 77

Advertisement

WOLF COFFEE SYSTEMS
Planning Information
The coffee system can be installed in a standard or flush
inset application. All 30" trim options are based on model
EC24/B. The sides of the cabinetry opening must be ade-
quate to support installation of the mounting slides. Refer to
the illustration below.
Finish the edges of the opening. They may be visible when
the unit is slid forward.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Coffee System
TRIM OVERLAP
Top
Bottom
Sides
COMBINATION INSTALLATION
To install a coffee system above a cup warming drawer,
one opening for both units must be specified. To achieve
the minimum reveal between units, place the coffee system
support rails on top of the cup warming drawer, then secure
the rails to the sides of the cabinet. Any material between
the units will increase the horizontal reveal.
14"
(356)
10"
(254)
3
/
"
4
(19)
TYPICAL
Side support.
1
/
"
reveal is
(3)
8
MIN
100 lb
(45 kg)
24" MODEL
30" TRIM
3
3
/
"
/
"
(5)
(5)
16
16
0"
0"
(0)
(0)
11
7
/
"
3
/
"
(18)
(98)
16
8
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
Power Cord
grounded, 120 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
6'
(1.8 m)
|
wolfappliance.com
77

Hide quick links:

Advertisement

loading