Wolf SO27TM/S/TH Design Manual page 94

Advertisement

WOLF GAS RANGES
Planning Information
When installing against a combustible surface, a minimum
20"
riser is required. Follow all minimum clearances
(508)
to combustible surfaces shown in the illustration on the
following page.
A Wolf pro ventilation hood is recommended with the gas
range. If the range is to be installed without ventilation, a
36"
minimum clearance, 44"
(914)
countertop to combustible materials above the range is
required. Refer to page 120 for pro ventilation.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit, servicing only this appliance
is required.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
Power Cord
|
94
Wolf Customer Care 800.222.7820
for charbroiler, from
(1118)
grounded, 110/120 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
6'
(1.8 m)
GAS SUPPLY
3
A gas supply line of
/
"
rigid pipe must be provided to
(19)
4
the range. If local codes permit, a certified, 3'
1
3
/
"
or
/
"
ID flexible metal appliance connector is
(13)
(19)
2
4
recommended to connect the units
the gas supply line.
Wolf natural gas ranges will function up to 8,600'
altitude without adjustment. If the installation exceeds this
elevation, contact an authorized Wolf dealer for a high alti-
tude conversion kit. LP models do not require conversion.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
long,
(.9 m)
1
/
" NPT female inlet to
2
in
(2621 m)
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)