Download Print this page

Wolf SO27TM/S/TH Design Manual page 113

Advertisement

WOLF COOKTOP HOODS
Planning Information
Wolf cooktop ventilation hoods are recommended for
use with Wolf induction, electric and gas cooktops and
integrated modules. For ranges and rangetops, a Wolf pro
ventilation hood is recommended.
These hoods have a telescopic chimney flue. A flue exten-
sion is available through an authorized Wolf dealer.
Installation of the cooktop hood should be 30"
36"
from the bottom of the hood to the countertop.
(914)
Wall and island hoods require an internal, in-line or remote
blower assembly, avail able through an authorized Wolf
dealer. For local dealer information, visit the find a show-
room section of our website, wolfappliance.com. Refer to
ventilation recommendations on pages 126–129. Cooktop
hoods have a vertical discharge with 6"
Consult a qualified HVAC professional for specific installa-
tion and ducting applications.
ELECTRICAL
Installation must comply with all applicable electrical codes.
For wall hoods, locate the electrical supply within the
shaded area shown in the illustration below. For island
hoods, locate the electrical supply on the ceiling inside the
top of the hood. A separate circuit, servicing only this appli-
to
ance is required.
(762)
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
round duct.
(152)
SHADED AREA
18"
(457)
30"
Electrical location—all wall hoods.
grounded, 110/120 VAC, 60 Hz
LOCATE
ELECTRICAL
WITHIN
E
36"
(762) TO
(914) BOTTOM EDGE TO COUNTERTOP
15 amp dedicated circuit
|
wolfappliance.com
113

Hide quick links:

Advertisement

loading