WOLF INTEGRATED MODULES
Planning Information
GAS SUPPLY
3
A gas supply line of
/
"
rigid pipe must be provided
(19)
4
to the gas module. If local codes permit, a certified, 3'
1
3
long,
/
"
or
/
"
ID flexible metal appliance con-
(13)
(19)
2
4
nector is recommended to connect the units
female inlet to the gas supply line.
When multiple gas cooktops or modules are installed side
by side, they can receive their gas supply from a common
line. However, each unit must have its own regulator
installed between the mainline and the cooktop or module.
Wolf natural gas modules will function up to 10,250'
in altitude without adjustment and LP gas modules will
function up to 8,600'
(2621 m)
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
(.9 m)
1
/
" NPT
2
(3124 m)
. If the installation exceeds
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
|