WOLF DUAL FUEL RANGES
Planning Information
When installing against a combustible surface, a minimum
10"
riser is required for a 36" dual fuel range with
(254)
charbroiler or griddle and all 48" and 60" models. Follow all
minimum clearances to combustible surfaces shown in the
illustration on the following page.
A Wolf pro ventilation hood is recommended with the dual
fuel range. If the range is to be installed without ventilation,
minimum clearance, 44"
a 36"
(914)
from countertop to combustible materials above the range is
required. Refer to page 120 for pro ventilation.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply flush with the wall or floor and
within the shaded area shown in the illustration on the fol-
lowing page. A separate circuit, servicing only this appliance
is required.
Wolf dual fuel ranges have a terminal block that allows for a
3-wire or 4-wire installation.
ELECTRICAL REQUIREMENTS
SINGLE OVEN RANGE
Electrical Supply
Service
Total Amps
DOUBLE OVEN RANGE
Electrical Supply
Service
Total Amps
|
88
Wolf Customer Care 800.222.7820
for charbroiler,
(1118)
grounded, 240/208 VAC, 60 Hz
30 amp dedicated circuit
21
grounded, 240/208 VAC, 60 Hz
50 amp dedicated circuit
42.5
GAS SUPPLY
3
A gas supply line of
/
"
rigid pipe must be provided to
(19)
4
the range. If local codes permit, a certified, 3'
1
3
/
"
or
/
"
ID flexible metal appliance connector is
(13)
(19)
2
4
recommended to connect the units
the gas supply line.
Wolf natural gas ranges will function up to 10,250'
in altitude without adjustment and LP gas ranges will func-
tion up to 8,600'
. If the installation exceeds these
(2621 m)
elevations, contact an authorized Wolf dealer for a high
altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
long,
(.9 m)
1
/
" NPT female inlet to
2
(3124 m)
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)