WOLF GAS COOKTOPS
Planning Information
A minimum 2"
is required from the bottom of the
(51)
cooktop to combustible materials. If a cooktop is installed
above an oven, a minimum of
units.
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
Service
Receptacle
Power Cord
1
/
"
is required between
(6)
4
grounded, 120 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
6'
(1.8 m)
GAS SUPPLY
3
A gas supply line of
/
"
rigid pipe must be provided
(19)
4
to the cooktop. If local codes permit, a certified, 3'
1
3
long,
/
"
or
/
"
ID flexible metal appliance con-
(13)
(19)
2
4
nector is recommended to connect the units
inlet to the gas supply line.
Wolf natural gas cooktops will function up to 10,250'
in altitude without adjustment and LP gas cooktops
(3124 m)
will function up to 8,600'
(2621 m)
these elevations, contact an authorized Wolf dealer for a
high altitude conversion kit.
GAS REQUIREMENTS
NATURAL GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
LP GAS
Supply Pressure
Min Line Pressure
Max Regulator Pressure
(.9 m)
1
/
" NPT male
2
. If the installation exceeds
WC
5"
(12.5 mb)
7"
(17.5 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
WC
10"
(25 mb)
11"
(27.4 mb)
14"
, .5 psi
(34.9 mb)
(3.5 kPa)
|
wolfappliance.com