WOLF BUILT-IN OVENS
Planning Information
E AND L SERIES OVENS
E series ovens can be installed in a standard or flush inset
application (standard installation only for L series ovens).
If a cooktop is being installed above an oven, a minimum
1
of
/
"
is required between units. Location of the elec-
(6)
4
trical supply within the oven opening may require additional
cabinet depth.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT
Single Oven
Double Oven
TRIM OVERLAP
1
30" E Series Oven
/
1
30" L Series Oven
3
36" L Series Oven
/
|
22
Wolf Customer Care 800.222.7820
1
/
"
reveal is
(6)
4
MIN
250 lb
(113 kg)
400 lb
(181 kg)
TOP
BOTTOM
SIDES
1
11
"
/
"
/
"
(13)
(3)
(17)
2
8
16
1
11
/
"
/
"
/
"
(3)
(3)
(17)
8
8
16
1
9
"
/
"
/
"
(5)
(3)
(14)
16
8
16
ELECTRICAL
Installation must comply with all applicable electrical codes.
Locate the electrical supply for E and L series ovens flush
with the back wall and within the shaded area shown in the
illustrations on the following pages. For ease of installation,
the electrical supply for the oven can be placed in an adja-
cent cabinet within reach of the conduit.
Performance may be compromised if the electrical supply is
less than 240 volts.
The oven is supplied with a conduit consisting of two
insulated hot lead conductors and a bare ground conductor.
The wiring diagram covering the control circuit is provided
with the oven.
ELECTRICAL REQUIREMENTS
SINGLE OVEN
Electrical Supply
Service
Conduit
Total Amps
Max Connected Load
Min Supply Wire
DOUBLE OVEN
Electrical Supply
Service
Conduit
Total Amps
Max Connected Load
Min Supply Wire
grounded, 240/208 VAC, 60 Hz
30 amp dedicated circuit
4'
, 3'
for SO36U
(1.2 m)
(.9 m)
21
5.1 kW
L1, L2, ground—10 AWG
grounded, 240/208 VAC, 60 Hz
50 amp dedicated circuit
5'
(1.5 m)
37
8.9 kW
L1, L2, ground—10 AWG