a. Screw the Ethernet coaxial cable into one of the round screw-on type
connectors on the transceiver.
Use either one of the transceiver connectors.
b. Screw the other Ethernet coaxial cable into the other round screw-on type
connector on the transceiver.
4. Determine if a terminator should be installed.
TABLE 2-1 lists the cabling limitations for Ethernet.
5. If termination is required, install a 50-ohm terminator in the unused transceiver N
connector or at the end of the coaxial cable. Use a female double N-type connector.
shows the elements used in the installation process.
FIGURE 2-7
Ethernet cable
Transceiver drop cable
(coaxial or optical fiber)
Connecting Twisted Pair Ethernet to N-type Coaxial Cable
FIGURE 2-7
Vampire tap or N-type connectors
Transceiver
Hardware interface
10/100BASE-T
twisted-pair cable
Server
Chapter 2
Cabling the System
2-7