6. If you are installing or rearranging interface cables, remove the kick panel
(
FIGURE 2-2
To protect and organize the interface cables, place the cables behind the kick panel.
7. If it is necessary to remove the rear door, pull the hinge pins out of the hinges and
lift the door off.
2.2.2

Replacing the Rear Door and Kick Panel

1. If you removed the panel, secure the kick panel to the cabinet (
Interface cables should be placed between the bottom panel and the kick panel.
2. Place the rear door on the hinges on the cabinet.
3. Insert the hinge pins in the hinges.
2.3

Connecting the Power Cords

2.3.1

Enterprise 6500/5500 System Power Cord

1. Open the AC socket cover (
AC power cord.
2. Connect the other end of the AC power cord into a grounded wall outlet.
The outlet must be a 200-240 VAC 30A circuit, dedicated solely to the server cabinet,
as described in the site preparation instructions in Chapter 1.
Caution – Risk of electric shock. Do NOT turn on AC power to the unit yet.
3. Continue with Section 2.4 through Section 2.7 for further cabling instructions.
) by loosening the two screws on the kick panel.
FIGURE 2-2
) on the AC power sequencer and connect the
Chapter 2
).
FIGURE 2-2
Cabling the System
2-3