Codes - Vermont Castings NBST27 Installation And Operating Instructions Manual

Vented/unvented gas log set
Table of Contents

Advertisement

NBST27 Unvented Gas Log Set
18. Unvented gas heaters are a supplemental zone heater.
They are not intended to be the primary heating appli-
ance.
19. Unvented gas heaters emit moisture into the living
area. In most homes of average construction, this
does not pose a problem. In houses of extremely
tight construction, additional mechanical ventilation is
recommended.
20. During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain
oils, fi lms or bonding agents. These chemicals are not
harmful but may produce annoying smoke and smells
as they are burned off during the initial operation of the
appliance; possibly causing headaches or eye or lung
irritation. This is a normal and temporary occurrence.
The initial break-in operation should last four hours to
properly cure logs and rock wool, with the burner at
the highest setting. Provide maximum ventilation by
opening windows or doors to allow odors to dissipate.
Any odors remaining after this initial break-in period
will be slight and will disappear with continued use.
21. Input ratings are shown in BTU per hour and are for
elevations up to 2,000 feet. For elevations above 2,000
feet, input ratings should be reduced 4 percent for each
1,000 feet above sea level. Refer to the National Fuel
Gas Code.
22. The appliance and its appliance main gas valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test pres-
sures in excess of 1/2 psig (3.5 kPa).
23. The appliance must be isolated from the gas supply
piping system by closing its equipment shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3.5 kPa).
24. Do not use this room heater if any part has been under
water. Immediately call a qualifi ed service technician
to inspect the room heater and to replace any part of
the control system and any gas control which has been
under water.
25. This appliance must not be used with glass doors in
the closed position. This can lead to pilot outages and
severe sooting outside the fi replace.
26. Never burn solid fuels in a fi replace where a unvented
room heater is installed.
27. Always have a fi replace screen in place when the
appliance is in operation and, unless other provisions
for combustion air are provided, the screen must have
an opening(s) for induction of combustion air.
4
IMPORTANT SAFETY INFORMATION
MASSACHUSSETTS RESIDENTS ONLY:
Refer to page 25 for additional information.
WARNING
Never connect unit to private (non-utility) gas wells.
This gas is commonly known as wellhead gas.
NBST27 is certifi ed to ANSI Z21.11.2
Latest Edition Unvented Heaters
& Z21.60 Latest Edition;
CSA 2.26 Latest Edition
WARNING
If the area in which the heater may be operated does
not meet the required volume for indoor combustion
air, combustion and ventilation air shall be provided
by one of the methods described in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, the International
Fuel Gas Code or applicable local codes.

CODES

Adhere to all local codes or, in their absence, the latest
edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1
or NFPA54 which can be obtained from...
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
or
81D3032

Advertisement

Table of Contents
loading

Table of Contents