FEATURES AND SPECIFICATIONS

CHECK PARTS:

Verify contents to ensure you have received all parts. You
should have the following:
Unvented Gas Log Burner Assembly
Crushed Volcanic Rock, 3 bags
Anchoring Screws, 2
Ceramic Fiber Logs
Rock wool
Flickering Bright Embers, 1 bag
On/Off Log Switch Assembly
Installation/Operating Instructions
The following options may be used with the milli-volt con-
trolled heater. These options are not packaged with the
log set.
Hand Held Remote with Receiver
Wall Thermostat with 15' Wire
Wall Switch with 15' Wire
Hand held Thermostat Remote with Receiver
Andirons
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.

ITEMS NEEDED FOR INSTALLATION:

You should have the following items available before pro-
ceeding with installation:
External regulator (for propane/LPG and 1/2 lb.
natural gas systems only)
Piping which complies with local codes
Sediment trap (recommended)
Screwdriver
Tee joint.
Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
Drill with 5/32 masonry bit
Pipe wrench or appropriate size crescent wrench
set
Manual shutoff valve
Gloves are recommended when handling
ceramic fi ber logs to prevent skin irritation
from loose fi bers. Logs are fragile; handle
with care.
81D3032
NBST27 Unvented Gas Log Set

GAS PRESSURES

Inlet Minimum
Inlet Maximum
Regulator Pressure
Setting
Pilot Regulator
GAS SPECIFICATIONS
Model
Fuel
NBST27NV
Natural
NBST27PV
LP
NATURAL GAS: An external regulator is required to reduce
supply pressure to a maximum of 10
systems operating at higher pressure.
PROPANE/LPG: An external regulator is required to reduce
supply pressure to a maximum of 13" w.c.

IGNITION CONTROLS

The piezo ignitor allows ignition of the pilot without the use
of matches or batteries.
Millivolt control has four (4) positions:
OFF:All gas to the gas logs is shut off at the valve.
IGN : Valve position to light/maintain a standing pilot.
ON: Valve position to turn ON/OFF log set with remote
switch/thermostat.
LOW/HI: Variable position to control fl ame height (heat
output).

PILOT/ODS

The gas log heater is fi tted with a specially designed safety
pilot (ODS assembly) which senses the amount of oxygen
available in the room and shuts the gas log heater off if the
oxygen level begins to drop below a satisfactory level. The
pilot can only be relit when adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fi tted with a millivolt (thermopile)
generator to provide power for remote activation.
Natural
Propane (LP)
5.0" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
11.0" w.c.
3.5" w.c.
n/a
Gas Rate
Max. Input
Min. Input
BTU/h
BTU/h
39,000
26,000
39,000
30,000
1
" w.c. on natural gas
2
5

Advertisement

Table of Contents
loading