Ms-01413 Mag Stripe Error - DataCard SP75 Manual

Hide thumbs Also See for SP75:
Table of Contents

Advertisement

MS-01413 Mag Stripe Error

End Sentinel error reading data on track 1, 2, or 3.
What is an End Sentinel?
An End Sentinel is special data used when encoding a magnetic stripe. It
is not the data you enter.
Possible Cause 1: The card has dirt or damage on the magnetic stripe.
Solution 1: Send the card to print again. If the message appears a second
time, run a printer cleaning card.
Possible Cause 2: The magnetic stripe on the card is Low Coercivity
material and the High Coercivity setting is selected.
Solution 2: To use the cards you have, select the Low Coercivity setting. To
encode with High Coercivity, obtain High Coercivity cards. Make sure the
cards work with your magnetic stripe reader.
If you cannot fix the problem, contact your service provider for assistance.
Related Topics:
"Cleaning the printer" on page 21