MS-01404, MS-01405, MS-01406 Mag Stripe Error

Parity error reading data on track 1, 2 or 3.
What is Parity?
Parity is special data used when encoding a magnetic stripe. It is not the
data you enter.
Possible Cause 1: The card has dirt or damage on the magnetic stripe.
Solution 1: Send the card to print again. If the message appears a second
time, run a printer cleaning card.
Possible Cause 2: The magnetic stripe on the card is Low Coercivity
material and the High Coercivity setting is selected.
Solution 2: To use the cards you have, choose the Low Coercivity setting
(in Diagnostics). To encode with High Coercivity, obtain High Coercivity
cards. Make sure the cards work with your magnetic stripe reader.
If you cannot fix the problem, contact your service provider for assistance.
Related Topics:
"Cleaning the printer" on page 21