Sanyo SAP-KRV91EH Technical & Service Manual page 57

Inverter split system air conditioner
Hide thumbs Also See for SAP-KRV91EH:
Table of Contents

Advertisement

PEOPLE SENSOR
Temperature sensor
Power ON/OFF switch
Sensitivity adjustment knob
Temperature sensor
People sensor
Power ON/OFF switch
Sensitivity adjustment
knob
Monitor lamp
Battery compartment
Address switch
OI-275-11EG
Names of Parts
This sensor detects human movement using changes in the infrared
rays given off by people. When people are detected in the vicinity of the
PEOPLE SENSOR during operation, the air conditioner is controlled so
that the surrounding room temperature reaches the temperature setting.
Also, this eliminates wasteful operation when people are not near the
remote control unit for added energy savings.
The figure below shows a cut-away view after the cover of the PEOPLE
SENSOR is slid open.
People sensor
This sensor detects the surrounding temperature.
This sensor detects when people are in the vicinity of the remote control
unit. Do not press on this section. Doing so could dent the sensor so
that it no longer operates normally.
Set to ON when using the People sensor. Set to OFF when not in use or
when replacing the batteries.
(Note this switch cannot start or stop operation of the air conditioner.)
This knob is used to adjust the sensitivity of the People sensor.
Weak – Strong: Adjust the sensitivity so that the sensor can detect
Continuous:
The monitor lamp lights up in the following cases.
When the Power ON/OFF switch is set to ON.
When the People sensor detects movement of people about one to six
minutes after the Power ON/OFF switch has been turned on.
When signals are sent at roughly 10-minute intervals during detection
by the People sensor
Inserting the Batteries
1. Set the Power ON/OFF switch to OFF.
2. Slide the cover down so that it comes off.
3. Insert four AAA alkaline batteries. Be sure that the + and – ends are
facing the correct direction.
4. Set the Power ON/OFF switch to ON. The indoor unit should make a
beeping sound to indicate that it has received the signal.
See the description for ADDRESS switch in the section ''Remote Control
Unit'' on page 10.
Monitor lamp
Battery compartment
3
2
4
1
Address switch
people in the required area under the room conditions.
This sets the air conditioner so that the People sensor
is always activated.
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-crv91eh

Table of Contents