Download Print this page
Sanyo SAP–KRV91EH Technical & Service Manual
Sanyo SAP–KRV91EH Technical & Service Manual

Sanyo SAP–KRV91EH Technical & Service Manual

Multi-split system air conditioner
Hide thumbs Also See for SAP–KRV91EH:

Advertisement

Quick Links

Notice
CORRECTION
SERVICE FLASH
Please add this notice to the TECHNICAL & SERVICE MANUAL listed below.
MULTI-SPLIT SYSTEM AIR CONDITIONER
Category :
SAP – KRV91EH + SAP–CRV91EH
Model :
Europe
Destination :
Serial No. :
1
Issue Number :
Indoor Model No.
SAP–KRV91EH
The reason for change
A : Correction
D : Design change
Reference No.
Old
SM700386
New SM700386-01
PRODUCTION CHANGE
ADDED INFORMATION
Product Code No.
Outdoor Model No.
1 852 065 78
SAP–CRV91EH
B : Quality reliability
E : Addition of parts
Page
Supplementary information for servicing
has been added.
FILE NO.
Product Code No.
Destination
1 852 065 79
C : Standardization
F : New information
Contents
REFERENCE NO.
Jun, 1999
Date :
Europe
Remarks
F
SM
700386–01

Advertisement

loading

Summary of Contents for Sanyo SAP–KRV91EH

  • Page 1 Notice CORRECTION PRODUCTION CHANGE SERVICE FLASH ADDED INFORMATION FILE NO. Please add this notice to the TECHNICAL & SERVICE MANUAL listed below. MULTI-SPLIT SYSTEM AIR CONDITIONER Jun, 1999 Category : Date : SAP – KRV91EH + SAP–CRV91EH Model : Europe Destination : Serial No.
  • Page 2: Supplementary Information

    SUPPLEMENTARY INFORMATION – Replacement Procedures for Outdoor Control PCB / Active Inverter PCB – These Installation Instructions provide the correct method for replacing the Control PCB and Active Inverter PCB on the outdoor unit. Since how they are mounted differs from the conventional PCB, their wiring method may not be easily apparent.
  • Page 3 Procedure for Replacing Control PCB If the Control PCB is faulty, remove and replace it using the following procedure: 1. To Remove Faulty PCB 1. Using a pliers or similar tool, disconnect the positive connectors of the leads (red: 1, white: 2) connected to the 3P terminal plate.
  • Page 4 Procedure for Replacing Active Inverter PCB The Active Inverter PCB cannot be replaced unless the Control PCB is first removed. If the Active Inverter PCB is faulty, remove the Control PCB as described on Page 2, Procedure for Replacing Control PCB and then remove and replace the Active Inverter PCB using the following procedure: 1.
  • Page 5 2. To Install New PCB 1. Connect three leads (IN1 / IN2 / E) to the new Active Inverter PCB. 2. Bind together the leads coming from near the coil (LO2) on the Active Inverter PCB and three leads connected in Step 1 above, using the new cable tie included with the product.
  • Page 6 SANYO Electric Co.,Ltd. Osaka, Japan 700386–01 06/99/200 Printed in Japan...