Biasi Inovia 25S ERP User Manual And Installation Instructions page 66

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for Inovia 25S ERP:
Table of Contents

Advertisement

PARAMETER
Not used
Not used
Not used
Minimum heating re-
turn temperature °C
Maintenance intervals
D.h.w. entry tempera-
ture
for
calculation
def=10
Correct pressure main
system (Pon)
Fig. 7.48
• Enter the "programming mode" by pressing
keys 12 - 15 - 16 (Fig. 7.49) for 10 seconds
at the same time until the letters P01 are
displayed on the LCD display and the value
of the parameter (41=Inovia 25S ERP), in-
dicating that "parameter 01" (Fig. 7.50) has
been activated.
9
10
11
12 13
Fig. 7.49
Fig. 7.50
• Scroll the various parameters using keys 15
or 16 until the letters P02 are displayed on
the LCD display, indicating that "parameter
- 66 -
COMMISSIONING
DIGIT
VALUES
P 24
---------------
P 25
---------------
P 26
---------------
P 27
P 28
P 29
P 30
17
16
15
14
02" has been activated.
• Press keys 9 or 10 to change the value and
confirm the value of the parameter with key
12.
• Press keys 15 or 16 (Fig. 7.49) to exit with-
out changing the value.
• Repeat all the above setting sequences in
order to visualize the parameters and their
values.
• Set the following parameters as hereafter
indicate:
PARAMETER
Pump speed
NTC on the c.h. re-
turn
• Exiting the "programming mode" is auto-
matic, after 15 minutes, or by cutting power.
VALUES
LCD
(SET)
P 03
00
P 18
01

Advertisement

Table of Contents
loading

Table of Contents