Procedure 7.24 - Replacing a Power Entry Module Fuse

Procedure
1.
Set the on/off switch in the off position. Remove the A.C. line cord from the A.C. outlet and
from the power entry module.
2.
Using a thin bladed screwdriver, carefully pry the fuse access door open.
3.
Using a thin bladed screwdriver, carefully pry the fuse module out of the power entry
module.
4.
The fuse module contains two fuses, carefully remove one or both fuses out of the fuse
module, as required.
5.
Insert the replacement fuse(s) into the fuse module. Use only 2 amp time delay fuses.
6.
Slide the fuse module back into the power entry module and close the fuse access door.
7.
Insert the A.C. line cord in the power entry module and the A.C. outlet.
Diagram 7.27 - Power Entry Module Fuse
8.
Set the on/off switch in the on position and test the EFX per Section Four.