Procedure 7.29 - Replacing a Power Entry Module Fuse
Procedure
1.
Set the on/off switch in the off position. Remove the A.C. line cord from the A.C. outlet and
from the power entry module.
2.
Using a thin bladed screwdriver, carefully pry the fuse access door open (See Diagram 7.31
or Diagram 7.32)).
Diagram 7.31 - Power Entry Module Fuse (serial codes CR and ST)
Power Entry Module
3.
Using a thin bladed screwdriver, carefully pry the fuse module out of the power entry
module.
4.
The fuse module contains two fuses, carefully remove one or both fuses out of the fuse
module, as required.
5.
Insert the replacement fuse(s) into the fuse module. Use only 2 amp time delay fuses.
6.
Slide the fuse module back into the power entry module and close the fuse access door.
7.
Insert the A.C. line cord in the power entry module and the A.C. outlet.
Fuse Module
5.33 Ellipitical Fitness Crosstrainer
Fuse
Fuse Access Door
Page 86